Absolute Humidity Calculator
Calculate the absolute humidity from temperature and relative humidity.
The formula
RH = e ÷ e_s(T); w = 0.622e ÷ (p − e)
Relative humidity is a ratio, not an amount
Saturation vapour pressure roughly doubles every 10 °C, so relative humidity compares the moisture present against a target that moves steeply with temperature. Air at 50% RH and 30 °C holds about twice the water of air at 50% RH and 20 °C. Warming air without adding water halves its RH, which is exactly why heated indoor air in winter feels so dry.
Dew point and mixing ratio are the absolute measures. Dew point is the temperature at which the air would saturate, so it tracks actual moisture content directly. Mixing ratio — grams of vapour per kilogram of dry air — is conserved as air rises and cools, which is why meteorologists work in it rather than in RH.
The wet-bulb temperature is the floor for evaporative cooling, and it matters for survivability: above about 35 °C wet bulb, sweating cannot shed metabolic heat at all, regardless of shade or wind.
A counter-intuitive result worth stating: moist air is lighter than dry air at the same temperature and pressure. Water has a molar mass of 18 against nitrogen's 28, so replacing nitrogen with vapour reduces density. That is what the virtual temperature captures.