Boiler Size Calculator

The boiler size calculator is here to help you know what size boiler to buy for your home.

Clear
Cooling needed2.6 tons31,200 BTU/h — buy a 3 ton unit
Nominal unit size3 tons36,000 BTU/h, the next half-ton up
Heating needed75,000 BTU/h21.98 kW · 75 MBH
Furnace size at 80% efficiency93,750 BTU/h input
Boiler size86,250 BTU/hwith 15% for pick-up and distribution
Cooling load per square foot20.8 BTU/h
Square feet per ton577400–600 is typical; much below 400 suggests something is wrong
Conditioned volume12,000 cu ft
Window contribution3,000 BTU/h150 sq ft of glazing at 20 BTU/h each

The formula

BTU/h = area × load factor; 1 ton of cooling = 12,000 BTU/h

Oversizing is worse than undersizing

An air conditioner that is too large cools the air quickly, satisfies the thermostat, and shuts off before it has removed much moisture. The result is a house that is cold and clammy, with the compressor short-cycling — which wastes energy and shortens its life.

These figures are a rule-of-thumb estimate. A real load calculation — Manual J in the US — accounts for the orientation of every wall, the specific windows, the measured air leakage and the local design temperatures, and it routinely comes out 20–30% below what a rule of thumb suggests.

Note the 400–600 square feet per ton range. If your answer falls far outside it, check the inputs before checking the arithmetic.